Order Nr. 868600 9V Internal Battery Required
(MEW0002001)
$475.00 Each
Order Nr. 868610 Includes 110VAC to 9V Powerpack
(MEW0002015)
$495.00 Each
Order Nr. 868620 Includes 220VAC to 9V Powerpack
(MEW0002001)
$495.00 Each
Ship Wt 8-lbs (4kg)
The E3 tester measures the performance of each footwear (left and right) and wristbands automatically. Colored LED monitoring lights and audible buzzer. Best tester on the market. Conforms to IEC 61340-5-1 standard (table 1).
Includes a wall mountable yellow panel with test instrument and easy instructions how to use.
Floor mount metal plate 15" square (380mm SQ).
Universal selection switch and adaptor allowing different standard grounding cords for wrist or footwear.
Includes Door Opener NO-NC Relay. Restricts access to static sensitive areas.
Power: Standard 9V internal battery (Optional 110V or 220V external power supply).
Battery duration: About 50,000 checks of 3 seconds duration.
Accuracy: +/- 10%
Environment condition (test conformity): 5°C to 70°C up to 80% Relative Humidity
Audible Alarm: Sounds on Red "Fail" mode.
Test voltage: 28 Volt
Resistance Reference per IEC 61340-5-1 Standard
Wristband: Lower Limit 750x103 to Upper Limit 35x106ohm
Footwear (primary grounding) Lower Limit 100x103 to Upper Limit 35x106ohm
Footwear (combined grounding) Lower Limit 100x103 to Upper Limit 100x106ohm
------------
Note: When footwear is used in combination with wristbands, turn the Mode Selector on the E3 to the right position (shoe + hand symbols).
The testing range for the shoes will automatically switch to the correct values.